Service & Parts Manual original Instructions
Part Number 32Z3811GB
Issue 1
FAULT FINDING
ERROR CODES DISPLAYED23
Error
Code
Error Condition Description Trigger Possible Causes
Error
Level
System
Response
E 101
Magnetron failed
to energise
Detects a magnetron
is not working
correctly
The current
measured by the
current sensing
transformer
was outside of
tolerance.
Failure of
component/s in
the microwave
circuit
Critical
Display error
message until
system is
power cycled.
E 102
Heater incorrect
current
Detects a heating
element is not
working correctly
The current
measured by
the sensing
transformer on
the SRB was <1A
when heating
cycled on or >1A
when heating
cycled o.
If some current
>1A, one or more
heater elements
could have
failed. If current
measured <1A
possible wiring
fault stopping
power reaching
element.
Critical
Display error
message until
system is
power cycled.
E 103
Ambient overheat
>70°C
Detects if the controls
area is operating
above temperature
The ambient
temperature
measured on the
BTS and SRB was
>70°C
Cooling fan failed.
Cooling fan
wired incorrectly.
Inlet air too hot.
Blocked inlet
lter.
Critical
Display error
message
until ambient
controls area
temperature is
below 60°C
E 104
Magnetron /
Cavity Overheat
Detects if the cavity
and magnetrons are
above temperature
Cavity and
magnetron
overheat
thermostats
Cooling fan failed.
E103 / E106 not
triggering. Failed
SRB. Magnetron
failure. Wiring /
connection fault.
Blocked Inlet
lter.
Critical
Display error
message until
service call and
the magnetron
cools down or
the cavity stat
is reset.
E 105
Supply voltage
high / low
Detects if the power
supply voltage is
outside specication
The power
supply to the
oven voltage
sensor on the
SRB measures
too high / low
Incorrect
mains voltage.
Poor internal /
external wiring
connections.
Faulty SRB.
Critical
Display error
message until
system power
cycled.
E 106
Cavity reaches
25°C above
setpoint once
it has been
controlling at
setpoint
Detects if the cavity
temperature has risen
above limits
The setpoint of
the oven was
exceeded
Cavity re. Failed
convection fan.
No impeller or
loose impeller on
convection fan.
Critical
Display error
message until
system is
power cycled.
E 107
Communication
error
No communication
can be made
between the BTS and
SRB
Loss of
communication
between the SBR
and BTS
SRB / BTS
connection cable
unplugged or
damaged. Faulty
BTS or SRB.
Critical
Display error
message until
system is
power cycled.
E 108 BTS PM error
Wrong PM found / no
PM found
The BTS or SRB
either has an
incorrect PM
(Personality
Module) tted or
no PM is tted
The PM has been
changed and is
incorrect. The
PM has been
removed.
Critical
Display error
message until
system is
power cycled.